blowdown pipe in Vietnamese

@Chuyên ngành kỹ thuật
-ống tháo
-ống xả

Sentence patterns related to "blowdown pipe"

Below are sample sentences containing the word "blowdown pipe" from the English - Vietnamese Dictionary. We can refer to these sentence patterns for sentences in case of finding sample sentences with the word "blowdown pipe", or refer to the context using the word "blowdown pipe" in the English - Vietnamese Dictionary.

1. Blowdown Tanks A Blowdown tank is a vessel designed to accept boiler Blowdown water and safely discharge the flash steam to a vent

2. The Blowdown tank is different from the Blowdown separator because it stores the water collected

3. Blowdown Tanks A Blowdown tank is a vessel designed to accept boiler Blowdown water and safely discharge the flash steam to a vent

4. Blowdown piping should be at least the same size as the Blowdown tapping on the boiler

5. Blowdown may refer to: Windthrow or forest Blowdown, a felling of trees by windstorm Blowdown stack, a vertical containment structure at a refinery or chemical plant Boiler Blowdown, a steam-boiler process to remove impurities

6. An accident in a nuclear reactor in which a cooling pipe bursts causing the loss of essential coolant British Dictionary definitions for Blowdown (2 of 2)

7. The Blowdown tank is different from the Blowdown separator because it stores the water collected

8. Blowdown is the removal of water from a boiler with the help of a Blowdown valve

9. Figure 3 below shows the input to Blowdown, and Figure 4 shows a schematic generated by Blowdown

10. Industrial boilers have three types of Blowdown procedures:

11. K064 Acid plant blowdown slurry and sludge resulting from the thickening of blowdown slurry from primary copper production.

12. Pipe junctions, pipe couplings, pipe fittings, pipe valves, flange adapters

13. IMPORTANT: Before using the Blowdown tank for the first time or operating the steam generator equipped with an automatic Blowdown valve, the Blowdown Tank must be filled with cold water to the center of the gauge glass level

14. Blowdown discards a portion of the concentrated circulating water.

15. Blowdown of the flowlines should be manually activated and depressurized independent of the facilities-wide emergency Blowdown associated with a confirmed fire or gas detection

16. Heat Recovery Systems, Blowdown Tanks and Separators, Orifice Meters

17. BC3150 Blowdown Controller: English: IM-P403-88: Download PDF: BC3200 and BC3210 Blowdown Controllers: English: IM-P403-53-US: Download PDF: BC3250 Blowdown Controller: English: IM-P403-89: Download PDF: BCS1 Pipeline Set: English: IM-P403-55-US: Download PDF: BCV Blowdown Control Valves half inch to 2inch: English: IM-P403_103-US: Download PDF

18. Skimmer Blowdown is the most efficient means of controlling cycles of concentration, but bottom Blowdown is essential to prevent the build-up of sludge

19. Madden Engineered Products, LLC has a complete line of products covering both the boiler’s continuous surface water Blowdown and the intermittent bottom water Blowdown

20. ‘The scale of the Blowdown was the first problem.’ ‘For a small Blowdown, we recorded data on all gap - makers.’ ‘The H + S forest had a considerable amount of slash left from the logging, and pit and mound topography was created from the Blowdown of large trees.’ ‘In 1985 a large section was affected by another large Blowdown.’

21. ‘The scale of the Blowdown was the first problem.’ ‘For a small Blowdown, we recorded data on all gap - makers.’ ‘The H + S forest had a considerable amount of slash left from the logging, and pit and mound topography was created from the Blowdown of large trees.’ ‘In 1985 a large section was affected by another large Blowdown.’

22. A liquid Blowdown should never be sent the facility flare …

23. Metal pipe couplings, pipe fittings, pipe connectors, manually operated valves, flange adapters

24. Blowdown separators are typically utilized to dispose of boiler blowoff/Blowdown, however, they can also be used for other high temperature sources such as deaerator […]

25. The most common method is the use of a conductivity controlled Blowdown system, consisting of a conductivity probe, a controller, and a motorized Blowdown valve