calomel electrode in Hungarian

kalomel-elektród

Sentence patterns related to "calomel electrode"

Below are sample sentences containing the word "calomel electrode" from the English - Hungarian Dictionary. We can refer to these sentence patterns for sentences in case of finding sample sentences with the word "calomel electrode", or refer to the context using the word "calomel electrode" in the English - Hungarian Dictionary.

1. The Calomel electrode is not a cell

2. Calomel electrode or saturated Calomel electrode (SCE) is used mainly as a reference electrode that is useful in calibrating other electrodes.

3. A cell is made of two electrodes, one Calomel electrode and another one

4. Calomel electrode definition is - a reference electrode consisting of mercury, Calomel, and potassium chloride solution.

5. The Calomel electrode consists of a broad glass tube having sidearm as shown in the figure

6. The sidearm is used for dipping it any solution used for coupling the Calomel electrode

7. The reaction occurring in the Calomel electrode is the reaction you present as "overall cell reaction"

8. Calomel electrode one capable of both collecting and giving up chloride ions in neutral or acidic aqueous

9. A Calomel electrode is a type of reference electrode that is based on reactions between mercury (I) chloride (Calomel) and elemental mercury

10. Saturated Calomel Electrode (SCE) The SCE is a half cell composed of mercurous chloride (Hg 2 Cl 2, Calomel) in contact with a mercury pool

11. Answer Calomel electrode is a metal-sparingly soluble salt electrode. It is used as secondary reference electrode to determine the standard potentials of the electrode

12. A good non-polarizable Calomel electrode is very robust, which is why is it used by many two-electrode systems where the supporting electrolyte is a non-reactive chloride salt.

13. The key difference between Calomel and glass electrode is that the Calomel electrode is a type of reference electrode, whereas the glass electrode is a non-reference electrode.

14. The study was performed to evaluate the usefulness of the silver sulfide-silver electrode for measuringsulfldes in foods by means of the electromotive force of the cell saturated calomel electrode/S2−/Ag2S, Ag.

15. Calomel electrode: [ e-lek´trōd ] either of two terminals of an electrically conducting system or cell; specifically, the uninsulated portion of a lead that is in direct contact with the body

16. The experiments were conducted using a conventional electrochemical cell with three electrodes, where a saturated Calomel electrode (SCE) was employed as reference electrode and a platinum wire was used as counter-electrode.

17. The following data are presented relative to the saturated calomel electrode (SCE) in acetonitrile: + / +0.38 V + / −0.94 V + / −1.41 V These data clearly indicate the stability of neutral ferrocene and the cobaltocenium and rhodocenium cations.

18. A three-electrode cell system was used consisting of a prepared low carbon steel with a surface of 1 x 1 [cm.sup.2] as working electrode, a saturated Calomel electrode as reference electrode, and a platinum (Pt) plate as a counter electrode.