pure tone in English

noun

stable frequency tone having no overtones

Use "pure tone" in a sentence

Below are sample sentences containing the word "pure tone" from the English Dictionary. We can refer to these sentence patterns for sentences in case of finding sample sentences with the word "pure tone", or refer to the context using the word "pure tone" in the English Dictionary.

1. Pure tone Audiometry:definition • measuring relative hearing threshold using pure tones is called pure tone Audiometry

2. PURE-TONE Audiometry The purpose of pure-tone Audiometry is to determine hearing threshold levels for pure tones

3. Practice: Pure tone Audiometry in diagnosing hearing loss

4. Audiometry, pure tone bone conduction Audiometry, and/or speech discrimination testing

5. The violinist had good intonation,[Sentencedict.com] and a wonderful pure tone.

6. Pure-tone Audiometry is the most commonly used test to measure auditory sensitivity

7. Depending on the type of screening Audiometer, the devices can be used for pure tone audiometry (hearing tests with a pure tone Audiometer) and/or for speech audiometry (language comprehension via a speech Audiometer).

8. An Audiogram is the graphical representation of the results of pure-tone air conduction tests

9. Pure-tone threshold Audiometry is the measurement of an individual's hearing sensitivity for calibrated pure tones

10. Pure tone Audiometry is the most common choice to evaluate hearing at a number of set frequencies

11. (Only 5% of acoustic neuromas have a normal auditory evaluation.) Pure tone and speech Audiometry should be performed

12. Pure tone Audiometry or pure-tone Audiometry is the main hearing test used to identify hearing threshold levels of an individual, enabling determination of the degree, type and configuration of a hearing loss and thus providing a basis for diagnosis and management

13. Audiometers are calibrated so that a 10-dB masking noise will block a 10-dB pure-tone signal

14. An Audiometer produces pure tone of various frequencies , atlemuates them to various intensity levels and delivers them to transducers

15. Pure-tone Audiometry is a subjective, behavioural measurement of a hearing threshold, as it relies on patient responses to pure

16. Audiometer AD104 is a basic diagnostic instrument that uses pure tone signals to check for hearing loss at various frequencies

17. The Maico Digital Pilot Audiometer provides fast hearing tests from a small and lightweight unit that includes an integrated pure tone Audiometer

18. A wide range of forms and sizes is possible and, most importantly, the Bells ring with a strong, pure tone that is unique to bronze

19. Pure tone Audiometries were performed on the pretreatment day and on the third, seventh, fourteenth post-treatment day, and on the first, second, third, sixth post-treatment month

20. MDH recommended Audiometers have test tones ranging from 250 to 8000 Hz and volumes of 0-80/100 decibels, this allows the screener to perform both pure tone

21. The Audiogram is a graph showing the results of a pure-tone hearing test. It will show how loud sounds need to be at different frequencies for you to hear them

22. As recommended in the ANSI S3.21-1978 (R.I 986) "Methods for Manual Pure-Tone Threshold Audiometry, the Audiogram shall be shown as a grid with frequency, in Hertz (Hz), represented logarithmically on the abscissa and hearing level …

23. The audiogram is usually obtained using a device called an Audiometer. A pure-tone Audiometer allows the practitioner to change the frequency of the sinusoid, change stimulus level (usually in 5-dB steps), route the sound to different transducers (earphone, maybe a bone vibrator, discussed later, or speakers), and to turn the signal on and off.

24. (i) In the case of Class 1 medical certificates and Class 2 medical certificates, when an instrument rating is to be added to the licence held, hearing shall be tested with pure tone audiometry at the initial examination and, at subsequent revalidation or renewal examinations, every 5 years until the age 40 and every 2 years thereafter.